| Item |
 |
 |
 |
| YS1700 |
YS170 |
SLPC*E |
| Front display |
|
Color full-dot LCD |
Full-dot LCD |
Meter |
| Analog display |
Available (bar and meter displays) |
Available (bar display) |
Available (meter display) |
| Digital display |
Available |
Available |
Not available |
| Trend display |
Available |
Available |
Not available |
| Alarm display |
LCD and LED |
LCD and LED |
LED |
| Dimensions |
72 x 144 x 250 mm (DIN) (or YS100 or YS80 housing) |
72 x 144 x 320 mm (DIN) or 87 x 182 x 480 mm (YS80 housing) |
87 x 182 x 480 mm |
| Weight |
1.6 Kg (Basic type) |
2.6 Kg |
5.4 Kg |
| User operations |
Via front panel |
Via front panel |
SV and MV: Via front panel
Parameters: Via side panel |
| Inputs |
Analog |
5 + 3 |
5 |
5 |
| Digital |
6 (total of DIs + DOs) + 4 DOs |
6 (total of DIs + DOs) |
6 (total of DIs + DOs) |
| Sensor direct |
1 (optional: mV, TC, RTD, potentiometer, isolator, twowire transmitter, or pulse; not available for the basic type) |
1 (optional: mV, TC, RTD, potentiometer, isolator, twowire transmitter, or pulse) |
Not available |
| Outputs |
Current |
1 or 2 |
1 or 2 |
1 |
| Voltage |
1+1 or 2+1 |
1 or 2 |
2 |
| Contacts |
6 (total of DIs + DOs) + 4 DOs |
6 (total of DIs + DOs) |
6 (total of DIs + DOs) |
| Fail contact |
1 |
1 |
1 |
| Transmitter power supply |
2 (standard),
or 1 isolated (optional) + 1 non-isolated (standard);
24 V DC, 60 mA with overcurrent protector |
2 (standard),
or 1 isolated (optional) + 1 non-isolated (standard);
24 V DC, 60 mA |
Not available |
| Control loop |
Single loop |
Available |
Available |
Available |
| Cascade |
Available |
Available |
Available |
| Selector |
Available |
Available |
Available |
| Dual loop |
Available |
Available |
Not available |
| PID calculation |
PID, P, sample PI, and batch PID |
PID, P, sample PI, and batch PID |
PID, sample PI, and batch PID |
| Control period |
50, 100, or 200 ms |
50, 100, or 200 ms |
100 or 200 ms |
| STC |
Available |
Available |
Available |
| Programming tool |
PC (USB connection) |
PC |
SPRG programmer |
| Programming method |
Text programming or function
block programming |
Text programming |
Text programming |
| Programming capacity |
Text programming: 1000 steps (main + sub) Function block programming: 400 modules |
400 steps (main and subprograms) |
Main: 99 steps
Sub: 99 steps |
| Hard manual device |
Available |
Available |
Not available |
| DCS communication |
Direct connection (CS 3000) or via SCIU (CS 1000/CS 3000) |
Direct connection (CS 3000) or via SCIU (CS 1000/CS 3000) |
Via SCIU (CS 1000/CS 3000) |
| RS-485 |
Modbus, PC-Link, or YS100 |
YS100 |
Via SCIU |
| Ethernet |
Modbus/TCP |
Not available |
Not available |