Model and Suffix Codes |
| Model |
Suffix Code |
Option Code |
Description |
| YS1700 |
|
|
Programmable indicating controller |
| YS1500 |
|
|
Indicating controller |
| YS1360 |
|
|
Indicator with alarm |
| YS1350 |
|
|
Manual setter for SV setting |
| YS1310 |
|
|
Manual setter for MV setting |
| |
-0 |
|
Always 0 |
| Type |
0 |
|
Basic type |
| 1 |
|
Basic type with expandable I/O (*1) |
| 2 |
|
Compatible type for YS100 (with YS100 case) |
| 3 |
|
Compatible type for YS80 internal unit, compatible type for EBS, I, EK and HOMAC (*2) |
| 4 |
|
Compatible type for YS80 (compatible size for YS80 with YS100 terminals) |
| 5 |
|
Compatible type for pneumatic 100 Line (with YS100 terminals) (*3) |
| Power supply |
0 |
|
100 V AC and 24 V DC dual power driven |
| 1 |
|
220 V AC |
| Direct sensor input (*4) |
/A01 |
mV input |
| /A02 |
Thermocouple input |
| /A03 |
RTD input |
| /A04 |
Potentiometer input |
| /A05 |
Isolator |
| /A06 |
Two-wire transmitter input (isolated) |
| /A07 |
Two-wire transmitter input (non-isolated) |
| /A08 |
Frequency input |
| Communication |
/A31 |
RS-485 communication (PC-link, Modbus, YS protocol, peer-to-peer) (*5) |
| /A32 |
DCS-LCS communication (*6) |
| /A34 |
Ethernet communication (Modbus/TCP) (*7) |
| Explosion-proof |
/FM |
FM nonincendive approved (FM Class I, Div 2) (*8) |
|
|
 |
| *1 |
Applicable to YS1700 only. This option comes with an I/O expansion terminal block (Model YS010) and a 3-meter I/O expansion cable (Model YS011). |
| *2 |
Fits into and can be connected to a YS80 housing (Model SHUP). (Model SHUP-410 EK- and HOMAC-compatible housing and Model SHUP-100 EBS and I Series-compatible housing need to be ordered separately.) |
| *3 |
A Line-compatible housing (Model 100) needs to be ordered separately. |
| *4 |
The direct sensor input option can only be specified with suffix code -02x, -04x, or -05x. Only one input type can be specified. |
| *5 |
Cannot be specified with suffix code -03x. Options A31 and A32 cannot be specified at the same time. |
| *6 |
Not applicable to Model YS1310. Options A31 and A32 cannot be specified at the same time. |
| *7 |
Option A32 can only be specified with suffix code -00x or -01x. |
| *8 |
Can only be specified with suffix code -00x or -01x. |
| Model |
Suffix Code |
Description |
|
| |
@Setting Software for YS1000 Series |
| -0 |
@Always 0 |
|
| 0 |
@Always 0 (with CD media and proprietary cable) |
|
|
|
|
|
|
Functional Restriction Depending on Suffix Code
|
 |
|
| SuffixCode |
Terminal Arrangement(Note 1) |
Expandable I/O |
Built-in Converters |
Use with Replacement Housing |
Ethernet |
RS-485 (Note 4) |
DCS-LCS Communication (Note 4) |
| -00x |
YS1000 |
|
|
|
 |
 |
 |
| -01x |
YS1000 with expandable I/O |
 |
|
|
 |
 |
 |
| -02x |
YS100-compatible |
|
 |
|
|
 |
 |
| -03x |
Connector (needs housing) |
|
|
(Note 2) |
|
|
 |
| -04x |
YS100-compatible |
|
 |
|
|
 |
 |
| -05x |
Connector (needs housing) |
|
 |
(Note 3) |
|
 |
 |
|
 |
| Note 1: |
Models YS1xx0-03x and -05x are supplied in a case compatible with internal units, so they need housing for signal wiring. |
| Note 2: |
Use one of the following housing according to your purpose: |
| |
|
| |
| Instrument to Be Replaced |
Housing to Be Used |
| YS80 Series |
SHUP-000 |
| I Series or EBS Series |
SHUP-100 |
| EK or HOMAC Series |
SHUP-420 |
|
|
|
| |
|
| Note 3: |
Use the housing below where necessary: |
| |
|
| |
| Instrument to Be Replaced |
Housing to Be Used |
| 100 Line pneumatic instrument |
YS006 |
|
|
|
| |
|
| Note 4: |
RS-485 and DCS-LCS communication cannot be used together. |
| Note 5: |
Applicable to YS1700-01x only. |
|
|
 |
|
 |